ANALISIS EFISIENSI BOILER DENGAN METODE INPUT– OUTPUT DI PT. JAPFA COMFEED INDONESIA Tbk. UNIT BANJARMASIN

  • Imam Muzaki Universitas Lambung Mangkurat
  • Aqli Mursadin Universitas Lambung Mangkurat
Keywords: Palm Shell, Efficiency, Heat Rate, Commissioning, Boiler

Abstract

This paper shows some of the research results. The result of this research shows that the boiler efficiency at operational condition (present) is 79,32% decreased efficiency equal to 9,19% compared with operational condition with efficiency as big as 88,51%. One of the factors analyzing the declining efficiency of the boiler is greatly influencing the heat transfer process, because if there is dirt or crust on the boiler pipe and the fouling, it will result in the process of heat transfer will decrease so that the heat transfer rate will decrease, and will also affect the amount of heat losses in the boiler.

Downloads

Download data is not yet available.

References

DAFTAR PUSTAKA

Djokosetyardjo, IR. M. J, 2003, Ketel Uap, Cetakan Kelima, Pradnya Paramita. Jakarta.

El-Wakil, M.M. 1985. Power Plant Techology. New York:McGraw-Hill Book.

Gaol , D. P., L. 2015. Analisa Efisiensi Water Tube Boiler Berbahan Bakar Fiber, Cangkang Sawit Dan Kulit Kayu Menggunakan Metode Langsung. Skripsi. Universitas Sumatera Utara. Medan.

UNEP. 2006. Peralatan Energi Panas Boiler & Pemanas Fluida Thermis, Pedoman Efisiensi Energi Untuk Industri Di Asia.

http://www.indobioethanol.com diakses pada 27 Februari 2015.

Published
2019-06-13
How to Cite
[1]
I. Muzaki and A. Mursadin, “ANALISIS EFISIENSI BOILER DENGAN METODE INPUT– OUTPUT DI PT. JAPFA COMFEED INDONESIA Tbk. UNIT BANJARMASIN”, SJMEkinematika, vol. 4, no. 1, pp. 37-46, Jun. 2019.