REMAINING LIFE ASSESSMENT OF SHELL COOLER CL-5 USING FITNESS FOR SERVICE (FFS)-1/API 579
Abstract
This research aims to evaluate the remaining life of the CL-5 shell cooler using the fitness for service method (FFS-1/API 579). The evaluation is conducted through the inspection process of components using Non-Destructive Testing (NDT) methods. This study is aimed at identifying thickness changes, analyzing the types of corrosion occurring in the CL-5 shell cooler, calculating the minimum allowable shell thickness, determining the Maximum Allowable Working Pressure (MAWP), estimating the corrosion rate, assessing the remaining life, and determining the operational feasibility of these components. Calculations are performed using the FFS-1/API 579 standard. The research results indicate that the total loss in 2011 and 2021 was 0.2 mm and 0.414 mm, respectively. The corrosion rates observed on the CL-5 shell cooler in 2011 and 2021 were 0.067 mm/year and 0.13 mm/year. Based on the minimum thickness and MAWP values evaluation, the CL-5 shell cooler is still fit for operation. Analysis of the remaining life of the CL-5 shell cooler indicates that the remaining life in 2011 and 2021 was 7.81 years and 6.83 years, respectively. Based on the above description, it can be concluded that the CL-5 shell cooler can still be operated.
Downloads
References
Direktorat Jenderal Minyak dan Gas Bumi: Pembangunan Jaringan Gas Bumi Untuk Rumah Tangga, Jakarta: Kementerian ESDM, 2012.
N. L. Widyastuti and H. Nugroho, "Dampak Covid-19 terhadap Industri Minyak dan Gas Bumi: Rekomendasi Kebijakan untuk Indonesia," The Indonesian Journal of Development Planning, vol. IV, no. 2, pp. 167-173, 2020.
E. Pujiyulianto, A. Muhyi, F. Paundra, F. Perdana, H. T. Yudistira and M. Syaukani, "Failure analysis of a wear ring impeller," Engineering Failure Analysis , vol. 138, no. 106415, pp. 1-13, 2022.
F. Yushandiana, H. Setiana and E. Pujiyulianto, "Case Study: The Failure Analysis of Pipe ASTM A351 HK-40 in Reaction Plant Unit," Journal of Failure Analysis and Prevention, vol. 20, p. 663–670, 2020.
C. R. C. &. M. Hoerner, "Corrosion and Remaining Life Assessment," Journal of Failure Analysis and Prevention, vol. 22, p. 181–190, 2022.
Fitness for Service FFS-1/API 579, US: API Publishing, 2020.
S. N. G. E. V. G. &. A. I. L. G. V. Abushik, "Remaining Service Life Assessment of the Effect of Existing Defects on Turbine Rotors," Power Technology and Engineering, vol. 51, p. 557–561, 2018.
G. Zecheru, A. Dumitrescu, P. Yukhymets, A. Gopkalo and M. Mihovski , Assessment of the Remaining Strength Factor and Residual Life of Damaged Pipelines, Switzerland: Springer, 2017.
A. F. Rozie, N. Firdaus and D. Adnyana, "Analisis Keselamatan dan Kelayakan Penggunaan CNG Buffer Storage Tank Berbasis Metode Residual Life Assessment," Jurnal Ilmiah Teknik Mesin, vol. VIII, no. I, pp. 48-52, 2022.
J. Firmansyah, Inspection Ultrasonic Test of Cooler CL-5, Blora: KESDM, 2011.
ASME section II : Material Parts, US: ASME Boiler and Pressure Vessel Code an International Code, 2019.
J. I. L. Almeida, M. C. Rodrigues and K. D. V. Mi, "Modeling and Level 3 Fitness-for-Service Assessment of a Cylindrical Pressure Vessel with General Metal Loss in Conjunction with the Numerical Thermal Transient Analysis," Mechanics and Applications, vol. 6, pp. 83-90, 2014.
ASME Section VIII Division I: Pressure Vessel, US: ASME Boiler and Pressure Vessel Code an International Code , 2019.
API 510: Pressure Vessel Inspection Code In-Service Inspection, Rating, Repair, and Alteration,, US: API Publishing, 2014.
I. Jalaluddin and Rosmayani, "Efektifitas Inhibitor Ekstrak Tanin Kulit Kayu Akasia (Acacia Mangium) Terhadap Laju Korosi Baja Lunak (St.37) Dalam Media Asam Klorida," Teknologi Kimia Unimal, vol. 4, no. 1, pp. 89-99, 2015.
S. Hadi and Jurmalis, "Pengaruh Lingkungan Minyak Mentah Terhadap Laju Korosi Pada Pipa Baja Karbon dan Pipa Galvanis," Teknik Mesin, vol. 3, no. 2, pp. 66-69, 2013.
Copyright (c) 2023 Authors

This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.